COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Rigel Medical SafeTest 60 PAT Tester

  • Capable of multiple tests for comprehensive PAT testing
  • Low energy, high current bond testing ensures accuracy
  • Specifically designed with medical and laboratory equipment in mind

£1,195.00 EXC. VAT

IN STOCK

Description

Designed for use on a range of medical and laboratory equipment, the Rigel Medical SafeTest 60 PAT Tester can perform a range of tests that are essential to PAT testing in this specific sector. These include earth & touch bond testing; earth & enclosure leakage; ground & chassis leakage; equipment leakage; voltage testing; mains voltage measurement; and load current measurement. A specific high current, low energy earth bond test ensures accuracy and precision whilst insulation resistance measurement constitutes another important aspect of the tester.

A simple test process featuring automatic mains configuration checks and one-button-one-function testing means that the Rigel SafeTest 60 can be used comfortably by a novice. An extremely clear colour screen displays results and operational menus, thus making all functions as straightforward as possible.

The Rigel SafeTest 60 is small and light which allows it to be easily carried and transported. A carry case comes provided as standard to house the tester plus all the additional accessories: a bond test probe, detachable mains cable and calibration certificate. The PAT tester is covered by a two-year warranty.

Key Features:

  • Specifically designed for medical and laboratory equipment
  • Performs all major PAT testing functions
  • Accurate and precise results
  • Dynamic, colour screen clearly displays results
  • Streamlined test process for novice users
  • Easy to transport

Specification

Earth Continuity

  • Method: 2 wire ZAP technique.
  • Test Current: >± 200mADC into 2Ω
  • Max Test Voltage: 4-24Vrms o/c
  • Measuring Range (low range): 0.001 – 0.999Ω / 0.001Ω resolution
  • Measuring Range (mid range): 1.00 – 9.99Ω / 0.01Ω resolution
  • Measuring Range (high range): 10.0 – 19.9Ω / 0.1Ω resolution
  • Accuracy: ± 1% of value, ± 5mΩ
  • Circuit Protection: Test inhibited if ≥30VAC or DC at 4mm inputs

Insulation Resistance

  • Measurement: EUT to Earth
  • Voltage: 500VDC @1mA.
  • Maximum O/C Voltage: <600VDC
  • Range: 100K - 20MΩ ± 5% ± 2 digits
  • Resolution: 0.01MΩ
  • Short circuit current: <2mA

Powered Leakage Measurements

  • IEC 62353: Equipment Leakage (Direct)
  • IEC / AAMI 60601: Earth + Enclosure Leakage
  • NFPA-99: Ground + Chassis Leakage
  • IEC 61010: Touch Leakage, Touch Voltage
  • Test Voltage: Mains Supply Voltage
  • Measuring Range: 0.1- 9999µA (0.1-8000µA typical for IEC 61010)
  • Measurement/Display Resolution: 0.1µA
  • Accuracy: ± 2%, ± 5µA
  • Mains Reversal: Softkey
  • Single Fault Conditions: Open neutral via softkey; Open earth via softkey
  • Frequency Response: IEC 60601 – 62353, NFPA-99 and IEC 61010

Voltage measurement

  • Application: L-N, L-E, N-E and touch voltage (IEC 61010)
  • Range: 0.0V – 300VAC
  • Resolution: 0.1V
  • Accuracy: ± 2% ± 2 digits (between 10V – 270VAC)
  • Mains frequency: 45.0 – 66.0Hz
  • Resolution: 0.1Hz
  • Accuracy: Unspecified

EUT Load Current Measurement

  • Range: 0.0A – 20.0A
  • Resolution: 0.1A
  • Accuracy: ±5% ± 2 digits

Power Source

  • Maximum current rating: 20A @ 120V / 16A @ 230V
  • Duty cycle: 15A to 20A, 5 min. on/5 min. off; 10A to 15A, 7 min. on/3 min. off; 0A to 10A, continuous
  • Mains power: 90-264V 48-64Hz

Supplied Accessories

The Rigel Safetest 60 PAT Tester comes with:

  • Calibration certificate
  • Carrying case
  • Bond test probe with clip
  • Detachable mains cable
  • Electronic instruction manual
  • Quick start guide

Videos

Designed for use on a range of medical and laboratory equipment, the Rigel Medical SafeTest 60 PAT Tester can perform a range of tests that are essential to PAT testing in this specific sector. These include earth & touch bond testing; earth & enclosure leakage; ground & chassis leakage; equipment leakage; voltage testing; mains voltage measurement; and load current measurement. A specific high current, low energy earth bond test ensures accuracy and precision whilst insulation resistance measurement constitutes another important aspect of the tester.

A simple test process featuring automatic mains configuration checks and one-button-one-function testing means that the Rigel SafeTest 60 can be used comfortably by a novice. An extremely clear colour screen displays results and operational menus, thus making all functions as straightforward as possible.

The Rigel SafeTest 60 is small and light which allows it to be easily carried and transported. A carry case comes provided as standard to house the tester plus all the additional accessories: a bond test probe, detachable mains cable and calibration certificate. The PAT tester is covered by a two-year warranty.

Key Features:

  • Specifically designed for medical and laboratory equipment
  • Performs all major PAT testing functions
  • Accurate and precise results
  • Dynamic, colour screen clearly displays results
  • Streamlined test process for novice users
  • Easy to transport

Earth Continuity

  • Method: 2 wire ZAP technique.
  • Test Current: >± 200mADC into 2Ω
  • Max Test Voltage: 4-24Vrms o/c
  • Measuring Range (low range): 0.001 – 0.999Ω / 0.001Ω resolution
  • Measuring Range (mid range): 1.00 – 9.99Ω / 0.01Ω resolution
  • Measuring Range (high range): 10.0 – 19.9Ω / 0.1Ω resolution
  • Accuracy: ± 1% of value, ± 5mΩ
  • Circuit Protection: Test inhibited if ≥30VAC or DC at 4mm inputs

Insulation Resistance

  • Measurement: EUT to Earth
  • Voltage: 500VDC @1mA.
  • Maximum O/C Voltage: <600VDC
  • Range: 100K - 20MΩ ± 5% ± 2 digits
  • Resolution: 0.01MΩ
  • Short circuit current: <2mA

Powered Leakage Measurements

  • IEC 62353: Equipment Leakage (Direct)
  • IEC / AAMI 60601: Earth + Enclosure Leakage
  • NFPA-99: Ground + Chassis Leakage
  • IEC 61010: Touch Leakage, Touch Voltage
  • Test Voltage: Mains Supply Voltage
  • Measuring Range: 0.1- 9999µA (0.1-8000µA typical for IEC 61010)
  • Measurement/Display Resolution: 0.1µA
  • Accuracy: ± 2%, ± 5µA
  • Mains Reversal: Softkey
  • Single Fault Conditions: Open neutral via softkey; Open earth via softkey
  • Frequency Response: IEC 60601 – 62353, NFPA-99 and IEC 61010

Voltage measurement

  • Application: L-N, L-E, N-E and touch voltage (IEC 61010)
  • Range: 0.0V – 300VAC
  • Resolution: 0.1V
  • Accuracy: ± 2% ± 2 digits (between 10V – 270VAC)
  • Mains frequency: 45.0 – 66.0Hz
  • Resolution: 0.1Hz
  • Accuracy: Unspecified

EUT Load Current Measurement

  • Range: 0.0A – 20.0A
  • Resolution: 0.1A
  • Accuracy: ±5% ± 2 digits

Power Source

  • Maximum current rating: 20A @ 120V / 16A @ 230V
  • Duty cycle: 15A to 20A, 5 min. on/5 min. off; 10A to 15A, 7 min. on/3 min. off; 0A to 10A, continuous
  • Mains power: 90-264V 48-64Hz

The Rigel Safetest 60 PAT Tester comes with:

  • Calibration certificate
  • Carrying case
  • Bond test probe with clip
  • Detachable mains cable
  • Electronic instruction manual
  • Quick start guide