{"product_id":"kewtech-ezypat-plus-landlords-pat-testing-kit","title":"Kewtech EZYPAT Plus Landlords PAT Testing Kit","description":"\u003cp\u003eThe Kewtech EZYPAT Plus Landlords PAT Testing Kit is a practical solution for landlords and features a battery-powered EZYPAT Plus that performs load and run testing at 230V and 110V when connected to a suitable supply. With a portable design, the tester allows testing throughout a property without relying on a permanent mains connection. Automatic test sequences for Class I appliances, Class II appliances and extension leads help make inspections straightforward and consistent.\u003c\/p\u003e\n\u003cp\u003eThe tester performs earth continuity, insulation resistance, substitute leakage and extension lead polarity tests, with a 200mA continuity test current suitable for testing IT equipment. Selectable 250V and 500V insulation test voltages provide flexibility when testing surge-protected devices and extension leads, while the null function compensates for test lead resistance to improve measurement accuracy. A backlit LCD with clear PASS\/FAIL indications and colour-coded screen illumination makes results easy to interpret, and the tester can perform approximately 1,400–1,500 tests from a single set of batteries.\u003c\/p\u003e\n\u003cp\u003eThe kit includes a PAT Register Book, PAT Certificate Pad, pass, wrap and fail labels, and an IEC Cloverleaf Adaptor for equipment such as laptops and office equipment. The Test Meter PRO TMP989 Socket Tester provides a quick way to check 13A socket wiring before appliance testing, while the PL13 Plug Lockout and Padlock can be used to isolate faulty appliances from use until repairs are completed. Everything is supplied in a durable Test-Meter Kit Bag, and compatibility with the KEWPAT App allows test information to be stored and reports generated digitally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePAT Testing Kit Comparison Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"kits\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Business PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLandlords PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter Kit Bag\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Register Book\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Certificate Pad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Cloverleaf Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Adaptor Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e500 Pass labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e x 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Pass Wrap labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e200 Fail labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Tuff Tag Cable Wrap Labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 110V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 110V Appliance Adaptor and IEC Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A \u0026amp; 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEarth bond continuity test\u003c\/li\u003e\n\u003cli\u003eInsulation resistance test (250V \u0026amp; 500V)\u003c\/li\u003e\n\u003cli\u003eBattery powered\u003c\/li\u003e\n\u003cli\u003e110V \u0026amp; 230V load and run testing\u003c\/li\u003e\n\u003cli\u003eBacklit LCD display with red\/green indication\u003c\/li\u003e\n\u003cli\u003eAutomatic test sequences\u003c\/li\u003e\n\u003cli\u003eClass I, Class II, extension leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Conductor Resistance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring range: 0.00 - 20.00 Ω (NULL value inc)*\u003c\/li\u003e\n\u003cli\u003eOver-range indication: \u0026gt; 20.00 Ω\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01Ω\u003c\/li\u003e\n\u003cli\u003eOpen-circuit voltage: 5 V ±0.4 V DC\u003c\/li\u003e\n\u003cli\u003eMeasuring current: 200 mA DC (nominal value)\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±3%rdg ±5dgt\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay range: 30 - 270 V\u003c\/li\u003e\n\u003cli\u003eHi\/ Lo indication: \u0026lt; 30 V: No voltage indication; \u0026gt; 270 V: 270 V\u003c\/li\u003e\n\u003cli\u003eResolution \u0026amp; Accuracy: 1 V \u0026amp; ±3%rdg ±5dgt\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: 250V; 500V\u003c\/li\u003e\n\u003cli\u003eMeasuring range: 0.00 - 20.00 MΩ\u003c\/li\u003e\n\u003cli\u003eOver-range indication: \u0026gt; 20.00 MΩ\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01 MΩ\u003c\/li\u003e\n\u003cli\u003eNo-load voltage: 250 V DC +20%, -0% 500 V DC +20%, -0%\u003c\/li\u003e\n\u003cli\u003eShort-circuit current: 1.5 mA DC or less\u003c\/li\u003e\n\u003cli\u003eRated current: 1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±2%rdg±3dgt\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSubstitute Leakage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring range: 0.10 - 12.00 mA rms\u003c\/li\u003e\n\u003cli\u003eOver-range indication: \u0026gt; 12.00 mA\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01mA\u003c\/li\u003e\n\u003cli\u003eOpen-circuit voltage\/ Freq.: 30 V ±5 V rms \/ 50 Hz ±5%\u003c\/li\u003e\n\u003cli\u003eMeasuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±3%rdg±5dgt\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Test between L and N\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOpen-circuit voltage: 4.5 V ±0.5 V DC\u003c\/li\u003e\n\u003cli\u003eCriteria of judgement: 100 kΩ ±20 kΩ or less: LCD shows “\u0026lt;0.10 MΩ” and the measurement is halted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRun Leakage (Item: Load current \/ Leakage current)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMains voltage range: 100 - 253 V \/ 50 Hz\u003c\/li\u003e\n\u003cli\u003eMeasuring range: 0.10 - 13.00 A rms \/ 0.10 - 20.00 mA rms\u003c\/li\u003e\n\u003cli\u003eDisplay range: 0.00 - 13.00 A \/ 0.00 - 20.00 mA\u003c\/li\u003e\n\u003cli\u003eOver-range indication: \u0026gt; 13.00 A \/ \u0026gt; 20.00 mA\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01A \/ 0.01mA\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±10%rdg ±5dgt \/ ±3%rdg ±5dvgt\u003c\/li\u003e\n\u003cli\u003erating: 3 kVA max., 15 sec. cont. \/ -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSupplied Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eKewtech EZYPAT Plus PAT Tester\u003c\/li\u003e\n\u003cli\u003eTest-Meter Kit Bag\u003c\/li\u003e\n\u003cli\u003ePAT Register Book\u003c\/li\u003e\n\u003cli\u003ePAT Certificate Pad\u003c\/li\u003e\n\u003cli\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/li\u003e\n\u003cli\u003eIEC Cloverleaf Adaptor\u003c\/li\u003e\n\u003cli\u003e2 x 500 Pass labels\u003c\/li\u003e\n\u003cli\u003e2x 250 Pass Wrap labels\u003c\/li\u003e\n\u003cli\u003e200 Fail labels\u003c\/li\u003e\n\u003cli\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/ueC3VtLs2nM\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Kewtech","offers":[{"title":"Default Title","offer_id":56872432828802,"sku":"KEWTEZYPATPLUSLKIT","price":485.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1723\/4673\/files\/Untitleddesign_4.png?v=1787741771","url":"https:\/\/www.pat-testers.co.uk\/products\/kewtech-ezypat-plus-landlords-pat-testing-kit","provider":"PAT-Testers.co.uk","version":"1.0","type":"link"}