{"product_id":"megger-pat120-landlords-pat-testing-kit","title":"Megger PAT120 Landlords PAT Testing Kit","description":"\u003cp\u003eThe Megger PAT120 Landlords PAT Testing Kit is a practical solution for carrying out routine portable appliance testing in rented accommodation. The kit is built around the Megger PAT120 and can test Class I and Class II appliances, extension leads and power leads, with automatic test sequences helping to speed up inspections and clear PASS\/FAIL indications making results easy to understand.\u003c\/p\u003e\n\u003cp\u003eEarth continuity, insulation resistance at 250 V and 500 V, and substitute leakage testing cover the key checks required for routine PAT testing, while the 250 V insulation test is useful for surge-protected extension leads. Battery-powered operation allows testing without a mains supply, while the rubber-armoured housing and toughened Gorilla glass help protect the tester when it is transported between properties. The kit includes accessories to support testing, safety and record keeping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePAT Testing Kit Comparison Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"kits\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Business PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLandlords PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter Kit Bag\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Register Book\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Certificate Pad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Cloverleaf Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Adaptor Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e500 Pass labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e x 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Pass Wrap labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e200 Fail labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Tuff Tag Cable Wrap Labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 110V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 110V Appliance Adaptor and IEC Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A \u0026amp; 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSimple pass fail indication \u0026amp; measurement\u003c\/li\u003e\n\u003cli\u003eRugged and hard wearing design\u003c\/li\u003e\n\u003cli\u003eBattery powered and portable\u003c\/li\u003e\n\u003cli\u003eAutomatic test sequences for Class I, Class II and Extension\/Power leads\u003c\/li\u003e\n\u003cli\u003eIncludes 250V Insulation testing for surge protected extension leads.\u003c\/li\u003e\n\u003cli\u003eProtective outer casing with front cover and toughened glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eOperating ambient: 20°C\u003c\/li\u003e  \u003cli\u003eHumidity: Nominal humidity\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eContinuity Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: Compliance Voltage: +4V dc, –0 % \/+10 % (open circuit)\u003c\/li\u003e  \u003cli\u003eTest current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)\u003c\/li\u003e  \u003cli\u003eContinuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)\u003c\/li\u003e  \u003cli\u003eResistance resolution: 10 mΩ\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.01 to 19.99Ω\u003c\/li\u003e  \u003cli\u003eContinuity test nulling: up to 9.99 Ω\u003c\/li\u003e  \u003cli\u003eTest time: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eInsulation Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eInsulation test: 250V dc –0 % \/+25 % open circuit, 500V dc –0 % \/+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load\u003c\/li\u003e  \u003cli\u003eShort circuit\/charge current: \u0026lt; 2mA dc\u003c\/li\u003e  \u003cli\u003eInsulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)\u003c\/li\u003e  \u003cli\u003eResolution: 0.01 MΩ\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 MΩ to 99.99 MΩ\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSubstitute Leakage Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eLeakage current: Accuracy ± 5% ± 3 digits\u003c\/li\u003e  \u003cli\u003eTest frequency: Nominal mains frequency 50Hz\u003c\/li\u003e  \u003cli\u003eTest voltage: \u0026lt; 50V ac\u003c\/li\u003e  \u003cli\u003eResolution: 0.01mA\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 to 19.99mA\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 5 seconds\u003c\/li\u003e  \u003cli\u003eReading corrected to 230V ac.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSafety \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eInstrument designed to IEC 61010-1: 2012\u003c\/li\u003e  \u003cli\u003eTest leads designed to IEC 61010-031: 2005\u003c\/li\u003e  \u003cli\u003e300 volts to Earth Category II\u003c\/li\u003e  \u003cli\u003eMains fuse protection to 250 volts rms ac\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eDesign to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eOperating temperature range: 0°C to +40°C\u003c\/li\u003e  \u003cli\u003eStorage temperature range: -20°C to +60°C\u003c\/li\u003e  \u003cli\u003eHumidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C\u003c\/li\u003e  \u003cli\u003eMaximum altitude: 2,000m to full safety spec.\u003c\/li\u003e  \u003cli\u003eIP rating: IP40 (with front cover closed)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eBattery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)\u003c\/li\u003e  \u003cli\u003eWeight (PAT120 Only): 1150g\u003c\/li\u003e  \u003cli\u003eWeight (Shipping): 2370g\u003c\/li\u003e  \u003cli\u003eDimensions: 203 x 148 x 78mm\u003c\/li\u003e  \u003cli\u003eMegger Part Number: 1003-062\u003c\/li\u003e  \u003c\/ul\u003e\n\u003ch4\u003eSupplied Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMegger PAT120 Tester\u003c\/li\u003e\n\u003cli\u003eTest-Meter Kit Bag\u003c\/li\u003e\n\u003cli\u003ePAT Register Book\u003c\/li\u003e\n\u003cli\u003ePAT Certificate Pad\u003c\/li\u003e\n\u003cli\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/li\u003e\n\u003cli\u003eIEC Cloverleaf Adaptor\u003c\/li\u003e\n\u003cli\u003e2 x 500 Pass labels\u003c\/li\u003e\n\u003cli\u003e2x 250 Pass Wrap labels\u003c\/li\u003e\n\u003cli\u003e200 Fail labels\u003c\/li\u003e\n\u003cli\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/jAFc6tP8p8w\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Megger","offers":[{"title":"Default Title","offer_id":56872549122434,"sku":"MEGGPAT120LKIT","price":485.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1723\/4673\/files\/Untitleddesign_13.png?v=1787745561","url":"https:\/\/www.pat-testers.co.uk\/products\/megger-pat120-landlords-pat-testing-kit","provider":"PAT-Testers.co.uk","version":"1.0","type":"link"}