{"product_id":"megger-pat150-landlords-pat-testing-kit","title":"Megger PAT150 Landlords PAT Testing Kit","description":"\u003cp\u003eThe Megger PAT150 Landlords PAT Testing Kit is a practical solution for property managers and letting agents built around the PAT150 to test Class I, Class II and Class III (SELV) appliances, as well as extension leads, with earth continuity, insulation resistance and substitute leakage testing covering the essential checks for PAT testing.\u003c\/p\u003e\n\u003cp\u003eAdditional mains-powered earth leakage, touch current and portable RCD tests allow users to assess a wider range of equipment, while adjustable pass limits and test durations provide flexibility for different appliances and testing requirements. Battery-powered operation makes it suitable for inspections where mains power is unavailable, and the rugged rubber armour and toughened Gorilla glass help protect the tester when travelling between properties. The kit includes accessories to support testing, record keeping and safe working practices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePAT Testing Kit Comparison Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"kits\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Business PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLandlords PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter Kit Bag\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Register Book\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Certificate Pad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Cloverleaf Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Adaptor Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e500 Pass labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e x 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Pass Wrap labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e200 Fail labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Tuff Tag Cable Wrap Labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 110V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 110V Appliance Adaptor and IEC Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A \u0026amp; 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComplies fully with the latest version of the IET Code of Practice\u003c\/li\u003e\n\u003cli\u003eSimple pass fail indication \u0026amp; measurement with adjustable PASS limits\u003c\/li\u003e\n\u003cli\u003eRugged and hard wearing design\u003c\/li\u003e\n\u003cli\u003eRechargeable version available (Megger PAT150R)\u003c\/li\u003e\n\u003cli\u003eBattery powered, portable design\u003c\/li\u003e\n\u003cli\u003eIncludes 250V Insulation testing for surge protected extension leads.\u003c\/li\u003e\n\u003cli\u003eAutomatic test sequences for Class I, Class II, Extension\/Power leads\u003c\/li\u003e\n\u003cli\u003e10mA and 30mA Portable RCD lead testing options\u003c\/li\u003e\n\u003cli\u003eSubstitute and Mains powered leakage testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eOperating ambient: 20°C\u003c\/li\u003e  \u003cli\u003eHumidity: Nominal humidity\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eContinuity Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: Compliance Voltage: +4V dc, –0 % \/+10 % (open circuit)\u003c\/li\u003e  \u003cli\u003eTest current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)\u003c\/li\u003e  \u003cli\u003eContinuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)\u003c\/li\u003e  \u003cli\u003eResistance resolution: 10 mΩ\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.01 to 19.99Ω\u003c\/li\u003e  \u003cli\u003eContinuity test nulling: up to 9.99 Ω\u003c\/li\u003e  \u003cli\u003eTest time: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eInsulation Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eInsulation test: 250V dc –0 % \/+25 % open circuit, 500V dc –0 % \/+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load\u003c\/li\u003e  \u003cli\u003eShort circuit\/charge current: \u0026lt; 2mA dc\u003c\/li\u003e  \u003cli\u003eInsulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)\u003c\/li\u003e  \u003cli\u003eResolution: 0.01 MΩ\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 MΩ to 99.99 MΩ\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSubstitute Leakage Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eLeakage current: Accuracy ± 5% ± 3 digits\u003c\/li\u003e  \u003cli\u003eTest frequency: Nominal mains frequency 50Hz\u003c\/li\u003e  \u003cli\u003eTest voltage: \u0026lt; 50V ac\u003c\/li\u003e  \u003cli\u003eResolution: 0.01mA\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 to 19.99mA\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 5 seconds\u003c\/li\u003e  \u003cli\u003eReading corrected to 230V ac.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eTouch Current Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: Nominal mains 230 V ac\u003c\/li\u003e  \u003cli\u003eTest frequency: Nominal mains 50 Hz\u003c\/li\u003e  \u003cli\u003eTest accuracy: ± 5% ± 3 digits\u003c\/li\u003e  \u003cli\u003eResolution: 0.01 mA\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 to 3.99 mA\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 5 sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSELV Device Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: 0 to 300 V ac\u003c\/li\u003e  \u003cli\u003eMeasurement accuracy: ± 3% ± 3 digits\u003c\/li\u003e  \u003cli\u003eResolution: 0.1 V ac\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.1 to 300 V ac\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eExtension Lead Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e\u003cem\u003eTest includes Insulation and Bond tests. \u003c\/em\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: 5V\u003c\/li\u003e  \u003cli\u003ePolarity: Lead OK, Live\/neutral shorted, Live\/neutral reversed, Live\/neutral open circuit\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003ePortable RCD Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: Nominal mains 230 V\u003c\/li\u003e  \u003cli\u003eTest frequency: 50Hz\u003c\/li\u003e  \u003cli\u003eTest current accuracy: +2% to +8% (1 x I, 5 x I)\u003c\/li\u003e  \u003cli\u003eTrip time accuracy: ±1% ± 1ms\u003c\/li\u003e  \u003cli\u003eTrip time resolution: 0.01ms\u003c\/li\u003e  \u003cli\u003eDisplay range: 0 to 200ms (1 x I), 0 to 40ms (5 x I)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eMains Supply Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eFrequency measurement range: 50 Hz\u003c\/li\u003e  \u003cli\u003eTest voltage: 40 to 300V ac\u003c\/li\u003e  \u003cli\u003eAccuracy: ± 3% ± 3 digits\u003c\/li\u003e  \u003cli\u003eResolution: 0.1Vac\u003c\/li\u003e  \u003cli\u003eDisplay range: 40 to 300V ac\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eCircuit Test\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e\u003cem\u003eCarried out automatically, not available to user.\u003c\/em\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: 5V\u003c\/li\u003e  \u003cli\u003eTest frequency: Nominal Mains 50 Hz\u003c\/li\u003e  \u003cli\u003eTest current: \u0026lt; 100mA short circuit\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSafety \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eInstrument designed to IEC 61010-1: 2012\u003c\/li\u003e  \u003cli\u003eTest leads designed to IEC 61010-031: 2005\u003c\/li\u003e  \u003cli\u003e300 volts to Earth Category II\u003c\/li\u003e  \u003cli\u003eMains fuse protection to 250 volts rms ac\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eDesign to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eOperating temperature range: 0°C to +40°C\u003c\/li\u003e  \u003cli\u003eStorage temperature range: -20°C to +60°C\u003c\/li\u003e  \u003cli\u003eHumidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C\u003c\/li\u003e  \u003cli\u003eMaximum altitude: 2,000m to full safety spec.\u003c\/li\u003e  \u003cli\u003eIP rating: IP40 (with front cover closed)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eBattery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)\u003c\/li\u003e  \u003cli\u003eWeight (PAT150 Only): 1300g\u003c\/li\u003e  \u003cli\u003eWeight (Shipping): 2795g \/ 2975g for PAT150R\u003c\/li\u003e  \u003cli\u003eDimensions: 203 x 148 x 78mm\u003c\/li\u003e  \u003cli\u003eMegger Part Number: 1003-064 \/ 1003-428 (rechargable model)\u003c\/li\u003e  \u003c\/ul\u003e\n\u003ch4\u003eSupplied Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMegger PAT150 PAT tester\u003c\/li\u003e\n\u003cli\u003eTest-Meter Kit Bag\u003c\/li\u003e\n\u003cli\u003ePAT Register Book\u003c\/li\u003e\n\u003cli\u003ePAT Certificate Pad\u003c\/li\u003e\n\u003cli\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/li\u003e\n\u003cli\u003eIEC Cloverleaf Adaptor\u003c\/li\u003e\n\u003cli\u003e2 x 500 Pass labels\u003c\/li\u003e\n\u003cli\u003e2x 250 Pass Wrap labels\u003c\/li\u003e\n\u003cli\u003e200 Fail labels\u003c\/li\u003e\n\u003cli\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/gIGCkAmzasc\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Megger","offers":[{"title":"Default Title","offer_id":56872802845058,"sku":"MEGGPAT150LKIT","price":605.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1723\/4673\/files\/Untitleddesign_15.png?v=1787751307","url":"https:\/\/www.pat-testers.co.uk\/products\/megger-pat150-landlords-pat-testing-kit","provider":"PAT-Testers.co.uk","version":"1.0","type":"link"}