{"product_id":"megger-pat150r-landlords-pat-testing-kit","title":"Megger PAT150R Landlords PAT Testing Kit","description":"\u003cp\u003eThe Megger PAT150R Landlords PAT Testing Kit is a practical solution for landlords and property managers carrying out routine portable appliance testing across rental properties. The PAT150R performs essential tests including earth bond continuity, insulation resistance, polarity and substitute leakage, with automatic test sequences for Class I and Class II appliances, IEC equipment and extension leads helping to simplify inspections. Portable RCD testing and earth\/touch leakage current measurements provide additional testing options where required, while the backlit display and clear PASS\/FAIL indications make results easy to interpret. Its rechargeable battery and integrated charger make it convenient to move between properties without relying on a mains supply. The kit includes accessories to support testing, record keeping and safe maintenance work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePAT Testing Kit Comparison Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"kits\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Business PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLandlords PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter Kit Bag\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Register Book\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Certificate Pad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Cloverleaf Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Adaptor Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e500 Pass labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e x 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Pass Wrap labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e200 Fail labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Tuff Tag Cable Wrap Labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 110V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 110V Appliance Adaptor and IEC Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A \u0026amp; 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cp\u003e\u003c!-- x-hugerte\/html --\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePurpose-built PAT testing kit for landlords and property managers\u003c\/li\u003e\n\u003cli\u003eAutomatic Class I, Class II, IEC lead and extension lead test sequences\u003c\/li\u003e\n\u003cli\u003ePerforms essential PAT tests plus RCD and leakage current measurements\u003c\/li\u003e\n\u003cli\u003eRechargeable PAT tester with integrated battery charger\u003c\/li\u003e\n\u003cli\u003eIncludes plug lockout and padlock for safer isolation of faulty appliances\u003c\/li\u003e\n\u003cli\u003eSupplied with documentation, certificates and appliance labels for complete record keeping\u003c\/li\u003e\n\u003cli\u003eIEC Cloverleaf Adaptor supports testing of compatible household and office equipment\u003c\/li\u003e\n\u003cli\u003ePortable kit bag for convenient transport between properties\u003c\/li\u003e\n\u003cli\u003eClear PASS\/FAIL indications simplify appliance assessment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating ambient: 20°C\u003c\/li\u003e\n\u003cli\u003eHumidity: Nominal humidity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContinuity Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage: Compliance Voltage: +4V dc, –0 % \/+10 % (open circuit)\u003c\/li\u003e\n\u003cli\u003eTest current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)\u003c\/li\u003e\n\u003cli\u003eContinuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)\u003c\/li\u003e\n\u003cli\u003eResistance resolution: 10 mΩ\u003c\/li\u003e\n\u003cli\u003eDisplay range: 0.01 to 19.99Ω\u003c\/li\u003e\n\u003cli\u003eContinuity test nulling: up to 9.99 Ω\u003c\/li\u003e\n\u003cli\u003eTest time: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation test: 250V dc –0 % \/+25 % open circuit, 500V dc –0 % \/+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load\u003c\/li\u003e\n\u003cli\u003eShort circuit\/charge current: \u0026lt; 2mA dc\u003c\/li\u003e\n\u003cli\u003eInsulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01 MΩ\u003c\/li\u003e\n\u003cli\u003eDisplay range: 0.10 MΩ to 99.99 MΩ\u003c\/li\u003e\n\u003cli\u003eTest duration: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSubstitute Leakage Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLeakage current: Accuracy ± 5% ± 3 digits\u003c\/li\u003e\n\u003cli\u003eTest frequency: Nominal mains frequency 50Hz\u003c\/li\u003e\n\u003cli\u003eTest voltage: \u0026lt; 50V ac\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01mA\u003c\/li\u003e\n\u003cli\u003eDisplay range: 0.10 to 19.99mA\u003c\/li\u003e\n\u003cli\u003eTest duration: User selectable from 2 sec to 5 seconds\u003c\/li\u003e\n\u003cli\u003eReading corrected to 230V ac.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTouch Current Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage: Nominal mains 230 V ac\u003c\/li\u003e\n\u003cli\u003eTest frequency: Nominal mains 50 Hz\u003c\/li\u003e\n\u003cli\u003eTest accuracy: ± 5% ± 3 digits\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01 mA\u003c\/li\u003e\n\u003cli\u003eDisplay range: 0.10 to 3.99 mA\u003c\/li\u003e\n\u003cli\u003eTest duration: User selectable from 2 sec to 5 sec\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSELV Device Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage: 0 to 300 V ac\u003c\/li\u003e\n\u003cli\u003eMeasurement accuracy: ± 3% ± 3 digits\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1 V ac\u003c\/li\u003e\n\u003cli\u003eDisplay range: 0.1 to 300 V ac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExtension Lead Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTest includes Insulation and Bond tests. \u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage: 5V\u003c\/li\u003e\n\u003cli\u003ePolarity: Lead OK, Live\/neutral shorted, Live\/neutral reversed, Live\/neutral open circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePortable RCD Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage: Nominal mains 230 V\u003c\/li\u003e\n\u003cli\u003eTest frequency: 50Hz\u003c\/li\u003e\n\u003cli\u003eTest current accuracy: +2% to +8% (1 x I, 5 x I)\u003c\/li\u003e\n\u003cli\u003eTrip time accuracy: ±1% ± 1ms\u003c\/li\u003e\n\u003cli\u003eTrip time resolution: 0.01ms\u003c\/li\u003e\n\u003cli\u003eDisplay range: 0 to 200ms (1 x I), 0 to 40ms (5 x I)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains Supply Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFrequency measurement range: 50 Hz\u003c\/li\u003e\n\u003cli\u003eTest voltage: 40 to 300V ac\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 3% ± 3 digits\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1Vac\u003c\/li\u003e\n\u003cli\u003eDisplay range: 40 to 300V ac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCarried out automatically, not available to user.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage: 5V\u003c\/li\u003e\n\u003cli\u003eTest frequency: Nominal Mains 50 Hz\u003c\/li\u003e\n\u003cli\u003eTest current: \u0026lt; 100mA short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstrument designed to IEC 61010-1: 2012\u003c\/li\u003e\n\u003cli\u003eTest leads designed to IEC 61010-031: 2005\u003c\/li\u003e\n\u003cli\u003e300 volts to Earth Category II\u003c\/li\u003e\n\u003cli\u003eMains fuse protection to 250 volts rms ac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature range: 0°C to +40°C\u003c\/li\u003e\n\u003cli\u003eStorage temperature range: -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eHumidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C\u003c\/li\u003e\n\u003cli\u003eMaximum altitude: 2,000m to full safety spec.\u003c\/li\u003e\n\u003cli\u003eIP rating: IP40 (with front cover closed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBattery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)\u003c\/li\u003e\n\u003cli\u003eWeight (PAT150 Only): 1300g\u003c\/li\u003e\n\u003cli\u003eWeight (Shipping): 2795g \/ 2975g for PAT150R\u003c\/li\u003e\n\u003cli\u003eDimensions: 203 x 148 x 78mm\u003c\/li\u003e\n\u003cli\u003eMegger Part Number: 1003-064 \/ 1003-428 (rechargable model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSupplied Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMegger PAT150R Tester\u003c\/li\u003e\n\u003cli\u003eTest-Meter Kit Bag\u003c\/li\u003e\n\u003cli\u003ePAT Register Book\u003c\/li\u003e\n\u003cli\u003ePAT Certificate Pad\u003c\/li\u003e\n\u003cli\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/li\u003e\n\u003cli\u003eIEC Cloverleaf Adaptor\u003c\/li\u003e\n\u003cli\u003e2 x 500 Pass labels\u003c\/li\u003e\n\u003cli\u003e2x 250 Pass Wrap labels\u003c\/li\u003e\n\u003cli\u003e200 Fail labels\u003c\/li\u003e\n\u003cli\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/gIGCkAmzasc\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"Megger","offers":[{"title":"Default Title","offer_id":56872857796994,"sku":"MEGGPAT150RLKIT","price":669.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1723\/4673\/files\/Untitleddesign_18.png?v=1787752136","url":"https:\/\/www.pat-testers.co.uk\/products\/megger-pat150r-landlords-pat-testing-kit","provider":"PAT-Testers.co.uk","version":"1.0","type":"link"}