{"product_id":"megger-pat150r-small-business-pat-testing-kit","title":"Megger PAT150R Small Business PAT Testing Kit","description":"\u003cp\u003eThe Megger PAT150R Small Business PAT Testing Kit is a practical solution for businesses carrying out routine portable appliance testing in-house. The PAT150R performs essential tests including earth bond continuity, insulation resistance, polarity and substitute leakage, with automatic test sequences for Class I and Class II appliances, IEC equipment and extension leads helping to speed up routine inspections.\u003c\/p\u003e\n\u003cp\u003ePortable RCD testing and earth\/touch leakage current measurements provide additional testing options where required, while clear PASS\/FAIL indications and a backlit display make results straightforward to interpret. Its rechargeable battery system allows the tester to be used without mains power, and the integrated charger makes it convenient to recharge between testing sessions. As a manual PAT tester without onboard memory, it is suited to businesses that prefer straightforward operation and manual record keeping. The kit includes accessories to support testing, socket checks and documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePAT Testing Kit Comparison Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"kits\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Business PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLandlords PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter Kit Bag\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Register Book\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Certificate Pad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Cloverleaf Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Adaptor Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e500 Pass labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e x 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Pass Wrap labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e200 Fail labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Tuff Tag Cable Wrap Labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 110V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 110V Appliance Adaptor and IEC Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A \u0026amp; 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComplete PAT testing kit designed specifically for small businesses\u003c\/li\u003e\n\u003cli\u003eAutomatic Class I, Class II and extension lead test sequences for faster testing\u003c\/li\u003e\n\u003cli\u003ePerforms advanced tests including portable RCD testing and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eIntegrated rechargeable battery system with built-in charger\u003c\/li\u003e\n\u003cli\u003eClear PASS\/FAIL indications and backlit display for easy result interpretation\u003c\/li\u003e\n\u003cli\u003eIncludes PAT register book, certificate pad and appliance labels for full documentation\u003c\/li\u003e\n\u003cli\u003eIEC adaptor kit supports testing of IT and office equipment\u003c\/li\u003e\n\u003cli\u003eSupplied in a portable Test-Meter kit bag for easy transport and storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eOperating ambient: 20°C\u003c\/li\u003e  \u003cli\u003eHumidity: Nominal humidity\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eContinuity Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: Compliance Voltage: +4V dc, –0 % \/+10 % (open circuit)\u003c\/li\u003e  \u003cli\u003eTest current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)\u003c\/li\u003e  \u003cli\u003eContinuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)\u003c\/li\u003e  \u003cli\u003eResistance resolution: 10 mΩ\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.01 to 19.99Ω\u003c\/li\u003e  \u003cli\u003eContinuity test nulling: up to 9.99 Ω\u003c\/li\u003e  \u003cli\u003eTest time: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eInsulation Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eInsulation test: 250V dc –0 % \/+25 % open circuit, 500V dc –0 % \/+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load\u003c\/li\u003e  \u003cli\u003eShort circuit\/charge current: \u0026lt; 2mA dc\u003c\/li\u003e  \u003cli\u003eInsulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)\u003c\/li\u003e  \u003cli\u003eResolution: 0.01 MΩ\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 MΩ to 99.99 MΩ\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 20 sec or selected during test to 180sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSubstitute Leakage Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eLeakage current: Accuracy ± 5% ± 3 digits\u003c\/li\u003e  \u003cli\u003eTest frequency: Nominal mains frequency 50Hz\u003c\/li\u003e  \u003cli\u003eTest voltage: \u0026lt; 50V ac\u003c\/li\u003e  \u003cli\u003eResolution: 0.01mA\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 to 19.99mA\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 5 seconds\u003c\/li\u003e  \u003cli\u003eReading corrected to 230V ac.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eTouch Current Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: Nominal mains 230 V ac\u003c\/li\u003e  \u003cli\u003eTest frequency: Nominal mains 50 Hz\u003c\/li\u003e  \u003cli\u003eTest accuracy: ± 5% ± 3 digits\u003c\/li\u003e  \u003cli\u003eResolution: 0.01 mA\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.10 to 3.99 mA\u003c\/li\u003e  \u003cli\u003eTest duration: User selectable from 2 sec to 5 sec\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSELV Device Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: 0 to 300 V ac\u003c\/li\u003e  \u003cli\u003eMeasurement accuracy: ± 3% ± 3 digits\u003c\/li\u003e  \u003cli\u003eResolution: 0.1 V ac\u003c\/li\u003e  \u003cli\u003eDisplay range: 0.1 to 300 V ac\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eExtension Lead Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e\u003cem\u003eTest includes Insulation and Bond tests. \u003c\/em\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: 5V\u003c\/li\u003e  \u003cli\u003ePolarity: Lead OK, Live\/neutral shorted, Live\/neutral reversed, Live\/neutral open circuit\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003ePortable RCD Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: Nominal mains 230 V\u003c\/li\u003e  \u003cli\u003eTest frequency: 50Hz\u003c\/li\u003e  \u003cli\u003eTest current accuracy: +2% to +8% (1 x I, 5 x I)\u003c\/li\u003e  \u003cli\u003eTrip time accuracy: ±1% ± 1ms\u003c\/li\u003e  \u003cli\u003eTrip time resolution: 0.01ms\u003c\/li\u003e  \u003cli\u003eDisplay range: 0 to 200ms (1 x I), 0 to 40ms (5 x I)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eMains Supply Test \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eFrequency measurement range: 50 Hz\u003c\/li\u003e  \u003cli\u003eTest voltage: 40 to 300V ac\u003c\/li\u003e  \u003cli\u003eAccuracy: ± 3% ± 3 digits\u003c\/li\u003e  \u003cli\u003eResolution: 0.1Vac\u003c\/li\u003e  \u003cli\u003eDisplay range: 40 to 300V ac\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eCircuit Test\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e\u003cem\u003eCarried out automatically, not available to user.\u003c\/em\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eTest voltage: 5V\u003c\/li\u003e  \u003cli\u003eTest frequency: Nominal Mains 50 Hz\u003c\/li\u003e  \u003cli\u003eTest current: \u0026lt; 100mA short circuit\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSafety \u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eInstrument designed to IEC 61010-1: 2012\u003c\/li\u003e  \u003cli\u003eTest leads designed to IEC 61010-031: 2005\u003c\/li\u003e  \u003cli\u003e300 volts to Earth Category II\u003c\/li\u003e  \u003cli\u003eMains fuse protection to 250 volts rms ac\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eDesign to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eOperating temperature range: 0°C to +40°C\u003c\/li\u003e  \u003cli\u003eStorage temperature range: -20°C to +60°C\u003c\/li\u003e  \u003cli\u003eHumidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C\u003c\/li\u003e  \u003cli\u003eMaximum altitude: 2,000m to full safety spec.\u003c\/li\u003e  \u003cli\u003eIP rating: IP40 (with front cover closed)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eBattery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)\u003c\/li\u003e  \u003cli\u003eWeight (PAT150 Only): 1300g\u003c\/li\u003e  \u003cli\u003eWeight (Shipping): 2795g \/ 2975g for PAT150R\u003c\/li\u003e  \u003cli\u003eDimensions: 203 x 148 x 78mm\u003c\/li\u003e  \u003cli\u003eMegger Part Number: 1003-064 \/ 1003-428 (rechargable model)\u003c\/li\u003e  \u003c\/ul\u003e\n\u003ch4\u003eSupplied Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMegger PAT150R Tester\u003c\/li\u003e\n\u003cli\u003eTest-Meter Kit Bag\u003c\/li\u003e\n\u003cli\u003ePAT Register Book\u003c\/li\u003e\n\u003cli\u003ePAT Certificate Pad\u003c\/li\u003e\n\u003cli\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/li\u003e\n\u003cli\u003eIEC Adaptor Kit\u003c\/li\u003e\n\u003cli\u003e2x 500 Pass labels\u003c\/li\u003e\n\u003cli\u003e250 Pass Wrap labels\u003c\/li\u003e\n\u003cli\u003e200 Fail labels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/gIGCkAmzasc\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Megger","offers":[{"title":"Default Title","offer_id":56872845279618,"sku":"MEGGPAT150RSBKIT","price":645.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1723\/4673\/files\/Untitleddesign_17.png?v=1787751938","url":"https:\/\/www.pat-testers.co.uk\/products\/megger-pat150r-small-business-pat-testing-kit","provider":"PAT-Testers.co.uk","version":"1.0","type":"link"}