{"product_id":"seaward-primetest-100-landlords-pat-testing-kit","title":"Seaward PrimeTest 100 Landlords PAT Testing Kit","description":"\u003cp\u003eThe Seaward PrimeTest 100 Landlords PAT Testing Kit is a practical choice for landlords carrying out routine electrical safety checks in rented properties. The battery-powered PrimeTest 100 provides simple manual testing for Class I and Class II appliances and IEC leads, with built-in test sequences, clear PASS\/FAIL results, 250V or 500V insulation testing, adjustable earth continuity limits and long lead testing. It can also check socket wiring and mains voltage before testing. Updated for the IET 5th Edition Code of Practice and compliant with BS EN 50699, it is suited to low-volume PAT testing without the complexity of a downloadable tester.\u003c\/p\u003e\n\u003cp\u003eThe kit includes a Test-Meter PRO TMP989 Socket Tester, IEC Cloverleaf Adaptor, PAT Register Book, PAT Certificate Pad, pass and fail labels, and a PL13 Plug Lockout and Padlock for isolating unsafe equipment. The PrimeTest 100 can also be used with the free Seaward PATMobile App for recording results, barcode scanning, photo tagging, label printing and report generation. Everything is supplied in a Test-Meter Kit Bag for convenient storage and transport between properties.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePAT Testing Kit Comparison Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"kits\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Business PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLandlords PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PAT Testing Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter Kit Bag\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Register Book\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePAT Certificate Pad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Cloverleaf Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC Adaptor Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e500 Pass labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e x 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Pass Wrap labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ex 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e200 Fail labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e250 Tuff Tag Cable Wrap Labels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 110V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 110V Appliance Adaptor and IEC Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e32A 230V Appliance Adaptor and Extension Lead Adaptor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e16A \u0026amp; 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e✔\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHandheld, battery-powered PAT tester for fast manual testing between appliances and properties\u003c\/li\u003e\n\u003cli\u003eUpdated for the IET 5th Edition Code of Practice and compliant with BS EN 50699\u003c\/li\u003e\n\u003cli\u003ePush-button test sequences for Class I appliances, Class II appliances and IEC leads\u003c\/li\u003e\n\u003cli\u003eClear digital display shows measured test values alongside PASS or FAIL indication\u003c\/li\u003e\n\u003cli\u003eSelectable 250V or 500V insulation resistance testing for greater flexibility across different appliance types\u003c\/li\u003e\n\u003cli\u003eUser-selectable earth continuity pass limits for controlled testing against appropriate thresholds\u003c\/li\u003e\n\u003cli\u003eLong lead testing for extension leads and appliances with longer mains leads\u003c\/li\u003e\n\u003cli\u003eClass II FE test sequence for suitable functional earth equipment\u003c\/li\u003e\n\u003cli\u003eIntegrated mains socket check for verifying socket wiring and mains voltage\u003c\/li\u003e\n\u003cli\u003eSeaward ZAP technology supports reliable earth continuity measurements through surface contamination\u003c\/li\u003e\n\u003cli\u003eCompatible with the Seaward PATMobile App for digital record keeping, barcode scanning, photo tagging, label printing and reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Continuity \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest Current: +\/- 200mA DC\u003c\/li\u003e\n\u003cli\u003eDisplay Range:  0.00 – 19.99Ω\u003c\/li\u003e\n\u003cli\u003ePass Value: 0.1\/0.2\/0.3 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest Voltages: 250\/500V DC\u003c\/li\u003e\n\u003cli\u003eDisplay Range: 0.20 – 19.99MΩ\u003c\/li\u003e\n\u003cli\u003ePass Value: 1\/2MΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIEC Lead Test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTests Performed:\n\u003cbr\u003e- Earth continuity\n\u003cbr\u003e- Insulation resistance\n\u003cbr\u003e- Live, neutral continuity and polarity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEquivalent Leakage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest Voltage: 40V, 50Hz, AC nominal\u003c\/li\u003e\n\u003cli\u003eDisplay Range: 0.1mA to 5.00mA\u003c\/li\u003e\n\u003cli\u003ePass Value: 5.00mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Socket test \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 230V +10%, -15% AC\u003c\/li\u003e\n\u003cli\u003eIndicators:\n\u003cbr\u003e- Phase to earth voltage\n\u003cbr\u003e- Phase to neutral voltage\n\u003cbr\u003e- Neutral to earth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Specifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 265 x 105 x 52mm (h x w x d)\u003c\/li\u003e\n\u003cli\u003eWeight: 800g\u003c\/li\u003e\n\u003cli\u003ePower Source: 6 x AA Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eSupplied Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSeaward PrimeTest 100 Pat Tester\u003c\/li\u003e\n\u003cli\u003eTest-Meter Kit Bag\u003c\/li\u003e\n\u003cli\u003ePAT Register Book\u003c\/li\u003e\n\u003cli\u003ePAT Certificate Pad\u003c\/li\u003e\n\u003cli\u003eTest Meter PRO TMP989 230V 13A Socket Tester\u003c\/li\u003e\n\u003cli\u003eIEC Cloverleaf Adaptor\u003c\/li\u003e\n\u003cli\u003e2 x 500 Pass labels\u003c\/li\u003e\n\u003cli\u003e2x 250 Pass Wrap labels\u003c\/li\u003e\n\u003cli\u003e200 Fail labels\u003c\/li\u003e\n\u003cli\u003ePL13 230V 13A Plug Lockout \u0026amp; Padlock\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/9MMxtwS7Jc8\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Seaward","offers":[{"title":"Default Title","offer_id":56873055256962,"sku":"SEAWPT100LKIT","price":439.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1723\/4673\/files\/Untitleddesign_21.png?v=1787756770","url":"https:\/\/www.pat-testers.co.uk\/products\/seaward-primetest-100-landlords-pat-testing-kit","provider":"PAT-Testers.co.uk","version":"1.0","type":"link"}