FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Seaward Primetest 250 Kit B

  • Smallest PAT tester to conform with IEE Code of Practice guidelines
  • Bespoke carry case has room for tester, labels and accessories
  • 110V adaptors allow testing on power tools and other construction equipment

£459.00 EXC. VAT

IN STOCK

Description

Limited Lifetime Warranty

The Seaward Primetest 250 Portable Appliance Tester offers simple operation for performing PAT testing, RCD testing and 3-phase testing. In addition this PAT tester also has a 250V DC insulation test for sensitive appliances and surge protected leads.

The auto test sequence buttons and clear display of Pass/Fail with test results make the Primetest 250 PAT tester perfect for both entry-level and intermediate users. With RCD and three-phase functionality, the PT250 is an extremely versatile PAT tester suitable for a testing a wide range of electrical appliances.

*This product qualifies for our exclusive Limited Lifetime Warranty. For more information please click here.

Seaward Primetest 250 PAT Testing Kit B Includes:

  • Seaward Primetest 250 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, 230V Extension Lead Adaptor, Mains Lead, Primetest 250 Instruction Manual, 6 x AA Batteries and Carry Case).
  • Seaward PAT Training Online Course Voucher
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Clover Leaf Adaptor
  • TEK989 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • PermaTAG Industrial Cable Labels
  • Seaward PATBag Carry Case

For more detailed information on the Seaward Primetest 250 Portable Appliance Tester please click here.

Kit A Kit B Kit C Kit D 3-Phase Kit
Seaward Primetest 250 PAT Tester
TEK989 Socket Tester
Earth Bond Lead & 230V Extension Lead
Seaward PATBag Carry Case, Mains Lead & 6 x AA Batteries
PAT Certificate Pad
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor
IEC PAT Adaptor Kit
110V Appliance Adaptor & 110V Extension Lead Adaptor
16A Three-Phase Adaptor
32A Three-Phase Adaptor
Microwave Leakage Detector &150 x Microwave Emission Labels
1000 Pass Labels, 200 Fail Labels & 250 PassWrap Cable Labels
100 PermaTAG Industrial Cable Labels
Seaward PATGuard Elements Manual PAT Software
Seaward PAT Training Online Course Voucher

Specification

Earth Continuity

  • Output Current - 200mA minimum into 2Ω
  • Test Voltage (o/c) - 9V DC nominal
  • Test Duration (Class I Test) - 2s nominal
  • Display Range - 0.01Ω to 19.99Ω
  • Pass Value (Class I Test) - 0.2Ω

Insulation Resistance

  • Test Voltage - 250/500V DC @1mA nominal, <2mA (s/c)
  • Test Duration (Class I or II) - 2s
  • Display Range - 0.01MΩ to 19.99MΩ
  • Pass Value - Class I: 1.0MΩ, Class II: 2.0MΩ

Equivalent Leakage

  • Test Voltage - 40V Nominal AC 50Hz Open Circuit
  • Test Duration - 2s
  • Display Range - 0.1mA to 19.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default)/0.25mA CL II

IEC Lead Test

  • Test Voltage - 5V DC Nominal
  • Test Duration - Time for Test (2s max)
  • Test - Live/Neutral Checks for o/c, s/c and crossed

Protective Conductor Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s Maximum
  • Display Range - 0.15mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

Touch Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s maximum
  • Display Range - 0.10mA to 3.50mA
  • Pass Value - 0.25mA

3 Phase Differential Leakage Current *Requires 3 phase adaptor accessory

  • Test Voltage - 3 phase supply voltage
  • Test Duration - Continuous measurements
  • Display Range - 0.10mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

RCD Trip Time

  • Test Voltage - Mains supply voltage
  • Test Current - 30mA/150mA rms sinusoidal
  • Test Current Phase - 0/180° auto switched on alternate tests
  • Measuring Range - 0ms to 500ms
  • Pass Value - 200ms

Power Socket Check

  • Input Voltage Range - 225-254V AC max current 13A UK
  •  Indicates configuration of voltage potentiall - Line to earth, line to neutral, neutral to earth

General

  • Memory Size - 999 Test Records
  • Power Source - 6 x AA Batteries

Supplied Accessories

Seaward Primetest 250 Kit B comes with:

  • Seaward Primetest 250 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, 230V Extension Lead Adaptor, Mains Lead, Primetest 250 Instruction Manual, 6 x AA Batteries and Carry Case).
  • Seaward PAT Training Online Course Voucher
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Clover Leaf Adaptor
  • TEK989 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • PermaTAG Industrial Cable Labels
  • Seaward PATBag Carry Case

Videos

 

Limited Lifetime Warranty

The Seaward Primetest 250 Portable Appliance Tester offers simple operation for performing PAT testing, RCD testing and 3-phase testing. In addition this PAT tester also has a 250V DC insulation test for sensitive appliances and surge protected leads.

The auto test sequence buttons and clear display of Pass/Fail with test results make the Primetest 250 PAT tester perfect for both entry-level and intermediate users. With RCD and three-phase functionality, the PT250 is an extremely versatile PAT tester suitable for a testing a wide range of electrical appliances.

*This product qualifies for our exclusive Limited Lifetime Warranty. For more information please click here.

Seaward Primetest 250 PAT Testing Kit B Includes:

  • Seaward Primetest 250 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, 230V Extension Lead Adaptor, Mains Lead, Primetest 250 Instruction Manual, 6 x AA Batteries and Carry Case).
  • Seaward PAT Training Online Course Voucher
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Clover Leaf Adaptor
  • TEK989 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • PermaTAG Industrial Cable Labels
  • Seaward PATBag Carry Case

For more detailed information on the Seaward Primetest 250 Portable Appliance Tester please click here.

Kit A Kit B Kit C Kit D 3-Phase Kit
Seaward Primetest 250 PAT Tester
TEK989 Socket Tester
Earth Bond Lead & 230V Extension Lead
Seaward PATBag Carry Case, Mains Lead & 6 x AA Batteries
PAT Certificate Pad
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor
IEC PAT Adaptor Kit
110V Appliance Adaptor & 110V Extension Lead Adaptor
16A Three-Phase Adaptor
32A Three-Phase Adaptor
Microwave Leakage Detector &150 x Microwave Emission Labels
1000 Pass Labels, 200 Fail Labels & 250 PassWrap Cable Labels
100 PermaTAG Industrial Cable Labels
Seaward PATGuard Elements Manual PAT Software
Seaward PAT Training Online Course Voucher

Earth Continuity

  • Output Current - 200mA minimum into 2Ω
  • Test Voltage (o/c) - 9V DC nominal
  • Test Duration (Class I Test) - 2s nominal
  • Display Range - 0.01Ω to 19.99Ω
  • Pass Value (Class I Test) - 0.2Ω

Insulation Resistance

  • Test Voltage - 250/500V DC @1mA nominal, <2mA (s/c)
  • Test Duration (Class I or II) - 2s
  • Display Range - 0.01MΩ to 19.99MΩ
  • Pass Value - Class I: 1.0MΩ, Class II: 2.0MΩ

Equivalent Leakage

  • Test Voltage - 40V Nominal AC 50Hz Open Circuit
  • Test Duration - 2s
  • Display Range - 0.1mA to 19.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default)/0.25mA CL II

IEC Lead Test

  • Test Voltage - 5V DC Nominal
  • Test Duration - Time for Test (2s max)
  • Test - Live/Neutral Checks for o/c, s/c and crossed

Protective Conductor Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s Maximum
  • Display Range - 0.15mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

Touch Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s maximum
  • Display Range - 0.10mA to 3.50mA
  • Pass Value - 0.25mA

3 Phase Differential Leakage Current *Requires 3 phase adaptor accessory

  • Test Voltage - 3 phase supply voltage
  • Test Duration - Continuous measurements
  • Display Range - 0.10mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

RCD Trip Time

  • Test Voltage - Mains supply voltage
  • Test Current - 30mA/150mA rms sinusoidal
  • Test Current Phase - 0/180° auto switched on alternate tests
  • Measuring Range - 0ms to 500ms
  • Pass Value - 200ms

Power Socket Check

  • Input Voltage Range - 225-254V AC max current 13A UK
  •  Indicates configuration of voltage potentiall - Line to earth, line to neutral, neutral to earth

General

  • Memory Size - 999 Test Records
  • Power Source - 6 x AA Batteries

Seaward Primetest 250 Kit B comes with:

  • Seaward Primetest 250 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, 230V Extension Lead Adaptor, Mains Lead, Primetest 250 Instruction Manual, 6 x AA Batteries and Carry Case).
  • Seaward PAT Training Online Course Voucher
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Clover Leaf Adaptor
  • TEK989 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • PermaTAG Industrial Cable Labels
  • Seaward PATBag Carry Case