The Kewtech EZYPAT Landlords PAT Testing Kit is a practical choice for landlords, letting agents and property managers who need to carry out routine appliance testing across rental properties. It combines the easy-to-use, battery-powered Kewtech EZYPAT tester with the accessories needed to test, record and identify appliances. Automatic test sequences for Class I appliances, Class II appliances and extension leads, together with clear PASS/FAIL indications and red and green visual alerts, make routine testing straightforward.

The EZYPAT performs earth bond continuity, insulation resistance, substitute leakage current and extension lead polarity tests, with 250V and 500V insulation test voltages providing flexibility when testing modern and surge-protected equipment. The kit also includes a Test Meter PRO socket tester for checking socket wiring before testing, an IEC cloverleaf adaptor for equipment such as laptop power supplies, and a PL13 230V 13A plug lockout and padlock for isolating failed appliances from use until they can be repaired or replaced.

For record keeping, the kit includes a PAT Register Book, PAT Certificate Pad and pass, wrap-around and fail labels for documenting results and identifying tested appliances. Everything is supplied in a durable Test-Meter kit bag, making it easy to organise and transport between properties.

PAT Testing Kit Comparison Guide

 

Small Business PAT Testing Kit

Landlords PAT Testing Kit

Maintenance PAT Testing Kit

Industrial PAT Testing Kit

Test Meter Kit Bag

x 2

PAT Register Book

PAT Certificate Pad

Test Meter PRO TMP989 230V 13A Socket Tester

   

IEC Cloverleaf Adaptor

 

   

IEC Adaptor Kit

 

500 Pass labels

x 2

x 2

x 2

 x 2

250 Pass Wrap labels

x2

x 2

x 2

200 Fail labels

250 Tuff Tag Cable Wrap Labels

   

16A 110V Appliance Adaptor and Extension Lead Adaptor

   

PL13 230V 13A Plug Lockout & Padlock

 

 

16A 230V Appliance Adaptor and Extension Lead Adaptor

   

32A 110V Appliance Adaptor and IEC Extension Lead Adaptor

     

32A 230V Appliance Adaptor and Extension Lead Adaptor

     

16A & 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors

     

Key Features

  • Earth bond continuity testing with 200mA test current
  • Quick and 5-second continuity testing
  • Insulation resistance testing at 250V and 500V
  • Substitute leakage current measurement
  • Test lead resistance compensation
  • Automatic test sequences for Class I, Class II and extension leads
  • Clear backlit LCD display
  • Instant PASS/FAIL indication with red and green visual alerts
  • Compact battery-powered operation
  • Supplied with documentation, adaptors, labels and carry bag

Specifications

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Mains Voltage

  • Display range: 30 - 270 V
  • Hi/ Lo indication: < 30 V: No voltage indication; > 270 V: 270 V
  • Resolution & Accuracy: 1 V & ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V; 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Insulation Test between L and N

  • Open-circuit voltage: 4.5 V ±0.5 V DC
  • Criteria of judgement: 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.

Run Leakage (Item: Load current / Leakage current)

  • Mains voltage range: 100 - 253 V / 50 Hz
  • Measuring range: 0.10 - 13.00 A rms / 0.10 - 20.00 mA rms
  • Display range: 0.00 - 13.00 A / 0.00 - 20.00 mA
  • Over-range indication: > 13.00 A / > 20.00 mA
  • Resolution: 0.01A / 0.01mA
  • Accuracy: ±10%rdg ±5dgt / ±3%rdg ±5dvgt
  • rating: 3 kVA max., 15 sec. cont. / -

Supplied Accessories

  • Kewtech EZYPAT Plus PAT Tester
  • Test-Meter Kit Bag
  • PAT Register Book
  • PAT Certificate Pad
  • Test Meter PRO TMP989 230V 13A Socket Tester
  • IEC Adaptor Kit
  • 2x 500 Pass labels
  • 250 Pass Wrap labels
  • 200 Fail labels

Videos

  

 

The Kewtech EZYPAT Landlords PAT Testing Kit is a practical choice for landlords, letting agents and property managers who need to carry out routine appliance testing across rental properties. It combines the easy-to-use, battery-powered Kewtech EZYPAT tester with the accessories needed to test, record and identify appliances. Automatic test sequences for Class I appliances, Class II appliances and extension leads, together with clear PASS/FAIL indications and red and green visual alerts, make routine testing straightforward.

The EZYPAT performs earth bond continuity, insulation resistance, substitute leakage current and extension lead polarity tests, with 250V and 500V insulation test voltages providing flexibility when testing modern and surge-protected equipment. The kit also includes a Test Meter PRO socket tester for checking socket wiring before testing, an IEC cloverleaf adaptor for equipment such as laptop power supplies, and a PL13 230V 13A plug lockout and padlock for isolating failed appliances from use until they can be repaired or replaced.

For record keeping, the kit includes a PAT Register Book, PAT Certificate Pad and pass, wrap-around and fail labels for documenting results and identifying tested appliances. Everything is supplied in a durable Test-Meter kit bag, making it easy to organise and transport between properties.

PAT Testing Kit Comparison Guide

 

Small Business PAT Testing Kit

Landlords PAT Testing Kit

Maintenance PAT Testing Kit

Industrial PAT Testing Kit

Test Meter Kit Bag

x 2

PAT Register Book

PAT Certificate Pad

Test Meter PRO TMP989 230V 13A Socket Tester

   

IEC Cloverleaf Adaptor

 

   

IEC Adaptor Kit

 

500 Pass labels

x 2

x 2

x 2

 x 2

250 Pass Wrap labels

x2

x 2

x 2

200 Fail labels

250 Tuff Tag Cable Wrap Labels

   

16A 110V Appliance Adaptor and Extension Lead Adaptor

   

PL13 230V 13A Plug Lockout & Padlock

 

 

16A 230V Appliance Adaptor and Extension Lead Adaptor

   

32A 110V Appliance Adaptor and IEC Extension Lead Adaptor

     

32A 230V Appliance Adaptor and Extension Lead Adaptor

     

16A & 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors

     

  • Earth bond continuity testing with 200mA test current
  • Quick and 5-second continuity testing
  • Insulation resistance testing at 250V and 500V
  • Substitute leakage current measurement
  • Test lead resistance compensation
  • Automatic test sequences for Class I, Class II and extension leads
  • Clear backlit LCD display
  • Instant PASS/FAIL indication with red and green visual alerts
  • Compact battery-powered operation
  • Supplied with documentation, adaptors, labels and carry bag

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Mains Voltage

  • Display range: 30 - 270 V
  • Hi/ Lo indication: < 30 V: No voltage indication; > 270 V: 270 V
  • Resolution & Accuracy: 1 V & ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V; 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Insulation Test between L and N

  • Open-circuit voltage: 4.5 V ±0.5 V DC
  • Criteria of judgement: 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.

Run Leakage (Item: Load current / Leakage current)

  • Mains voltage range: 100 - 253 V / 50 Hz
  • Measuring range: 0.10 - 13.00 A rms / 0.10 - 20.00 mA rms
  • Display range: 0.00 - 13.00 A / 0.00 - 20.00 mA
  • Over-range indication: > 13.00 A / > 20.00 mA
  • Resolution: 0.01A / 0.01mA
  • Accuracy: ±10%rdg ±5dgt / ±3%rdg ±5dvgt
  • rating: 3 kVA max., 15 sec. cont. / -
  • Kewtech EZYPAT Plus PAT Tester
  • Test-Meter Kit Bag
  • PAT Register Book
  • PAT Certificate Pad
  • Test Meter PRO TMP989 230V 13A Socket Tester
  • IEC Adaptor Kit
  • 2x 500 Pass labels
  • 250 Pass Wrap labels
  • 200 Fail labels