COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Megger PAT450 Kit 1

  • Megger PAT450 performs 110V, 230V and flash tests
  • Large internal memory capacity with space for 10,000 records
  • Instant appliance recognition through barcode scanner & printer

£1,579.00 EXC. VAT

IN STOCK

Description

The Megger PAT450 portable appliance tester offers dual voltage appliance safety testing and flash testing, ideal for efficient PAT testing on construction sites, production lines and in hire & repair shops.

In addition, the PAT450 tester has full database functionality with a 10,000 record memory that can be quickly downloaded to a PC for trending, analysis and traceability. Although an advanced PAT tester in terms of testing capabilities and functionality, the Megger 450 provides intuitive operation via direct access test buttons and simple data entry using the QWERTY keyboard.

The Megger PAT450 comes complete with a high duty cycle tailored towards efficient, continuous and repetitive appliance testing. This is the perfect choice for electricians, contractors and PAT testing professionals looking for a reliable and long term investment that is suited to almost any PAT testing application.

Megger PAT450 Tester Kit 1 (with Printer & Scanner) Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor

For more information on the Megger PAT450 PAT Tester please click here.

Kit 1 Kit 2 Kit 3
Megger PAT450 Tester
SimplyPATs V7 Software
PAT400 Barcode Label Printer
2x Printer Cartridges
PAT400 Barcode Scanner
Microwave Leakage Detector
50 Microwave Emissions Labels
Pass Labels 500 1000 1000
Fail Labels 200 400 400
PassWrap Cable Labels 250 250
110V Extension Lead Adaptor
IEC Adaptor Kit less IEC Clover
Earth Bond Test Lead
230V Extension Lead Adaptor
Calibration Certificate
PAT450 Carry Case

Specification

Earth Bond test (10A and 25A)

  • Open circuit voltage: 9V AC (Supply 230V)
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (0 to 1.99 Ω)
  • Display range: 0 to 1.99 Ω

Continuity test (200mA)

  • Voltage: 4V DC
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (1 to 19.99 Ω)
  • Display range: 0 to 19.99 Ω

Insulation test (250/500V)

  • Resistance accuracy: ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
  • Resistance resolution: 0.01 MΩ
  • Display range: 0 to 99.99 MΩ

Substitute leakage test

  • Voltage: 40V AC nominal mains frequency
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Differential leakage test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Touch current test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 10mA

Operational test

  • Voltage: Nominal mains supply
  • VA accuracy: ±5% ±10 digits (0 - 99 VA), ±5% ±50 digits (100 VA - 999 VA), ±5% ±100 digits (1000 VA - 3700 VA)
  • Resolution: 1 VA (0 to 3700 VA)
  • Display range: 0 to 3999 VA

Extension lead test

  • Tests performed: Bond, insulation and polarity
  • Polarity test voltage: 12V
  • Polarity checks: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C

Portable RCD test

  • Voltage: Nominal mains supply
  • Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ±5 digits
  • Trip time resolution: 0.1ms
  • Display range: 0 to 1999 ms (1/2 x I), 0 to 300 ms (1 x I), 0 to 40 ms (5 x I)

Fuse test

  • Voltage: 3.3V
  • Warning: Audible bleep if fuse is OK

Flash test

  • Voltage: 1500V AC for Class 1, 3000V AC for Class2
  • Current: <3.5 mA short circuit @ 253 V
  • Breakdown current accuracy: ±5% ±5 digits
  • Breakdown current resolution: 0.01mA
  • Display range: 0 to 3mA
  • Supply range: 230V at 50Hz, 110V at 50Hz
  • Compliance: IEC 61010-1, CAT II 300V, IEC 61326-1, 61326-2-2
  • Dimensions: 180 x 255 x 320mm
  • Weight: 5kg

Supplied Accessories

Megger PAT450 Tester Kit 1 (with Printer & Scanner) Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor

Videos

The Megger PAT450 portable appliance tester offers dual voltage appliance safety testing and flash testing, ideal for efficient PAT testing on construction sites, production lines and in hire & repair shops.

In addition, the PAT450 tester has full database functionality with a 10,000 record memory that can be quickly downloaded to a PC for trending, analysis and traceability. Although an advanced PAT tester in terms of testing capabilities and functionality, the Megger 450 provides intuitive operation via direct access test buttons and simple data entry using the QWERTY keyboard.

The Megger PAT450 comes complete with a high duty cycle tailored towards efficient, continuous and repetitive appliance testing. This is the perfect choice for electricians, contractors and PAT testing professionals looking for a reliable and long term investment that is suited to almost any PAT testing application.

Megger PAT450 Tester Kit 1 (with Printer & Scanner) Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor

For more information on the Megger PAT450 PAT Tester please click here.

Kit 1 Kit 2 Kit 3
Megger PAT450 Tester
SimplyPATs V7 Software
PAT400 Barcode Label Printer
2x Printer Cartridges
PAT400 Barcode Scanner
Microwave Leakage Detector
50 Microwave Emissions Labels
Pass Labels 500 1000 1000
Fail Labels 200 400 400
PassWrap Cable Labels 250 250
110V Extension Lead Adaptor
IEC Adaptor Kit less IEC Clover
Earth Bond Test Lead
230V Extension Lead Adaptor
Calibration Certificate
PAT450 Carry Case

Earth Bond test (10A and 25A)

  • Open circuit voltage: 9V AC (Supply 230V)
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (0 to 1.99 Ω)
  • Display range: 0 to 1.99 Ω

Continuity test (200mA)

  • Voltage: 4V DC
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (1 to 19.99 Ω)
  • Display range: 0 to 19.99 Ω

Insulation test (250/500V)

  • Resistance accuracy: ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
  • Resistance resolution: 0.01 MΩ
  • Display range: 0 to 99.99 MΩ

Substitute leakage test

  • Voltage: 40V AC nominal mains frequency
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Differential leakage test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Touch current test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 10mA

Operational test

  • Voltage: Nominal mains supply
  • VA accuracy: ±5% ±10 digits (0 - 99 VA), ±5% ±50 digits (100 VA - 999 VA), ±5% ±100 digits (1000 VA - 3700 VA)
  • Resolution: 1 VA (0 to 3700 VA)
  • Display range: 0 to 3999 VA

Extension lead test

  • Tests performed: Bond, insulation and polarity
  • Polarity test voltage: 12V
  • Polarity checks: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C

Portable RCD test

  • Voltage: Nominal mains supply
  • Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ±5 digits
  • Trip time resolution: 0.1ms
  • Display range: 0 to 1999 ms (1/2 x I), 0 to 300 ms (1 x I), 0 to 40 ms (5 x I)

Fuse test

  • Voltage: 3.3V
  • Warning: Audible bleep if fuse is OK

Flash test

  • Voltage: 1500V AC for Class 1, 3000V AC for Class2
  • Current: <3.5 mA short circuit @ 253 V
  • Breakdown current accuracy: ±5% ±5 digits
  • Breakdown current resolution: 0.01mA
  • Display range: 0 to 3mA
  • Supply range: 230V at 50Hz, 110V at 50Hz
  • Compliance: IEC 61010-1, CAT II 300V, IEC 61326-1, 61326-2-2
  • Dimensions: 180 x 255 x 320mm
  • Weight: 5kg

Megger PAT450 Tester Kit 1 (with Printer & Scanner) Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor