Metrel BetaPAT Plus Kit A

  • Tests at 230V and 110V with additional portable RCD testing
  • Internal memory for up to 6800 results
  • Choose between 100 auto test sequences or create your own

£999.00 EXC. VAT

IN STOCK

Description

The Metrel BetaPAT Plus portable appliance tester allows PAT testing of 110V and 230V appliances as well as portable RCD testing.

Speed and productivity are guaranteed with over 100 pre-programmed PAT test sequences and space for an additional 50 customised tests to make your appliance testing process as straightforward as possible.

The BetaPAT Plus is ideal for efficiently testing the electrical safety of almost any appliance and offers the unique ability for TRMS leakage and load current measurements using an additional current clamp adaptor.

The Metrel MI3304 BetaPAT Plus can store up to 6800 results which can be downloaded using Metrel PATLink Pro software for extended results management and professional report generation.

Metrel BetaPAT Plus PAT Testing Kit A Includes:

  • Metrel BetaPAT Plus MI3304 Tester (complete with Earth Bond Test Lead & Crocodile Clip, Portable RCD Test Probe, RS232 & USB Download Leads, BetaPAT Instruction Manual and Calibration Certificate).
  • Metrel PATLink Pro PAT Software
  • Metrel Barcode Scanner
  • 1000 Barcode Appliance ID Labels
  • Metrel PAT Testing DVD
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • IEC Adaptor Kit
  • 230V Extension Lead Adaptor
  • 1000 Pass Labels
  • 200 Fail Labels

For more information on the Metrel BetaPAT Plus PAT Tester please click here.

  Kit A Kit B
Metrel BetaPAT Plus MI3304 Tester
PATLink Pro Software  
PATLink Pro PLUS Software  
Barcode Scanner
1000 Barcode Scanner Labels
Metrel PAT Testing DVD  
Microwave Leakage Detector
150 Microwave Emission Labels
IEC Adaptor Kit
110V Extension Lead Adaptor  
230V Extension Lead Adaptor
1000 Pass Labels
200 Pass Labels

Specification

Earth Bond Continuity

  • Currents: 100mA DC, 4A, 10A or 25A AC
  • Measuring Range: 0.00-19.9 ohms

Insulation Test

  • Voltage: 250V or 500V DC
  • Measuring Range: 0.000 - 199.9 Mohms

Substitute Leakage

  • Voltage: 40V
  • Measuring range: 0.00- 1.99 mA

Touch Leakage

  • Measuring range: 0.00- 19.99 mA

Differential Leakage

  • Measuring range: 0.00- 19.99 mA

Load Test

  • Measuring range: 0 - 4 kVA

Polarity

  • Output Voltage: 40V
  • Faults: open, short, crossed, multiple fault

Portable RCD

  • Trip-out time readout: 0 ms - 1999 ms (½xI∆N) ±3 ms
  • Test currents: (I∆N)10 mA, 15 mA, 30 mA 0 ms - 300 ms (I∆N) ±3 ms
  • Test current multipliers ½,1, 2 and 5xI∆N 0 ms - 150 ms (2xI∆N) ±3 ms
  • Test modes: single, autotest 0 ms - 40 ms (5xI∆N) ±3 ms

Trip out times

  • ½xI∆N: t∆ > 300ms
  • 1xI∆N: t∆ < 300ms
  • 5xI∆N: t∆ <40ms

General

  • Dimensions: 335 x 160 x 335mm
  • Weight: 8.4kg

Supplied Accessories

Metrel BetaPAT Plus Kit A comes with:

  • Metrel BetaPAT Plus MI3304 Tester (complete with Earth Bond Test Lead & Crocodile Clip, Portable RCD Test Probe, RS232 & USB Download Leads, BetaPAT Instruction Manual and Calibration Certificate).
  • Metrel PATLink Pro PAT Software
  • Metrel Barcode Scanner
  • 1000 Barcode Appliance ID Labels
  • Metrel PAT Testing DVD
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • IEC Adaptor Kit
  • 230V Extension Lead Adaptor
  • 1000 Pass Labels
  • 200 Fail Labels

The Metrel BetaPAT Plus portable appliance tester allows PAT testing of 110V and 230V appliances as well as portable RCD testing.

Speed and productivity are guaranteed with over 100 pre-programmed PAT test sequences and space for an additional 50 customised tests to make your appliance testing process as straightforward as possible.

The BetaPAT Plus is ideal for efficiently testing the electrical safety of almost any appliance and offers the unique ability for TRMS leakage and load current measurements using an additional current clamp adaptor.

The Metrel MI3304 BetaPAT Plus can store up to 6800 results which can be downloaded using Metrel PATLink Pro software for extended results management and professional report generation.

Metrel BetaPAT Plus PAT Testing Kit A Includes:

  • Metrel BetaPAT Plus MI3304 Tester (complete with Earth Bond Test Lead & Crocodile Clip, Portable RCD Test Probe, RS232 & USB Download Leads, BetaPAT Instruction Manual and Calibration Certificate).
  • Metrel PATLink Pro PAT Software
  • Metrel Barcode Scanner
  • 1000 Barcode Appliance ID Labels
  • Metrel PAT Testing DVD
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • IEC Adaptor Kit
  • 230V Extension Lead Adaptor
  • 1000 Pass Labels
  • 200 Fail Labels

For more information on the Metrel BetaPAT Plus PAT Tester please click here.

  Kit A Kit B
Metrel BetaPAT Plus MI3304 Tester
PATLink Pro Software  
PATLink Pro PLUS Software  
Barcode Scanner
1000 Barcode Scanner Labels
Metrel PAT Testing DVD  
Microwave Leakage Detector
150 Microwave Emission Labels
IEC Adaptor Kit
110V Extension Lead Adaptor  
230V Extension Lead Adaptor
1000 Pass Labels
200 Pass Labels

Earth Bond Continuity

  • Currents: 100mA DC, 4A, 10A or 25A AC
  • Measuring Range: 0.00-19.9 ohms

Insulation Test

  • Voltage: 250V or 500V DC
  • Measuring Range: 0.000 - 199.9 Mohms

Substitute Leakage

  • Voltage: 40V
  • Measuring range: 0.00- 1.99 mA

Touch Leakage

  • Measuring range: 0.00- 19.99 mA

Differential Leakage

  • Measuring range: 0.00- 19.99 mA

Load Test

  • Measuring range: 0 - 4 kVA

Polarity

  • Output Voltage: 40V
  • Faults: open, short, crossed, multiple fault

Portable RCD

  • Trip-out time readout: 0 ms - 1999 ms (½xI∆N) ±3 ms
  • Test currents: (I∆N)10 mA, 15 mA, 30 mA 0 ms - 300 ms (I∆N) ±3 ms
  • Test current multipliers ½,1, 2 and 5xI∆N 0 ms - 150 ms (2xI∆N) ±3 ms
  • Test modes: single, autotest 0 ms - 40 ms (5xI∆N) ±3 ms

Trip out times

  • ½xI∆N: t∆ > 300ms
  • 1xI∆N: t∆ < 300ms
  • 5xI∆N: t∆ <40ms

General

  • Dimensions: 335 x 160 x 335mm
  • Weight: 8.4kg

Metrel BetaPAT Plus Kit A comes with:

  • Metrel BetaPAT Plus MI3304 Tester (complete with Earth Bond Test Lead & Crocodile Clip, Portable RCD Test Probe, RS232 & USB Download Leads, BetaPAT Instruction Manual and Calibration Certificate).
  • Metrel PATLink Pro PAT Software
  • Metrel Barcode Scanner
  • 1000 Barcode Appliance ID Labels
  • Metrel PAT Testing DVD
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • IEC Adaptor Kit
  • 230V Extension Lead Adaptor
  • 1000 Pass Labels
  • 200 Fail Labels